A regular sump pump stops when the power goes out. The usual fix is a battery backup pump in the same pit. North Dakota State University (NDSU) Extension says to use a deep-cycle battery and check it every six months. A generator can run the main pump, but only outdoors and at least 20 feet from the house, plugged in with heavy-duty extension cords, or through a transfer switch if it connects to your home's wiring. If your basement is flooded, stay out until the electric utility confirms the power is off. That advice comes from NDSU Extension, the Consumer Product Safety Commission (CPSC), Ready.gov and the Electrical Safety Foundation International (ESFI).
Quick answers
- A plug-in sump pump runs on house power, so it stops in an outage. A battery backup pump sits in the same sump and turns on only if the main pump fails (NDSU Extension).
- Use a deep-cycle lead-acid battery, sized near the backup pump maker's maximum, which NDSU says is typically around 120 amp-hours.
- Check the battery every six months for charge and corrosion, and test both pumps by lifting the float (NDSU Extension).
- A generator must run outdoors only. CPSC says at least 20 feet from homes and buildings. Never in a basement or garage, even with the door open (CPSC, NDSU Extension).
- Never wire a generator into the house without a transfer switch (NDSU Extension).
- Don't walk into a flooded basement until the utility confirms the power is off (ESFI).
- Keep carbon monoxide alarms on every level of your home (Ready.gov, CPSC).
For everything else to do when the lights go out, start with our what to do during a power outage checklist.
Why the pump stops, and what's at stake
NDSU Extension calls the sump pump "the first line of defense for many homeowners to prevent water from seeping into the basement." A standard sump pump runs on house power, and NDSU's own checklist starts with "Make sure the pump is plugged in." When the grid goes down, so does the pump.
That is why many homes add a second pump. NDSU Extension says, "Because of power outages or sump pump failure, many houses have additional protection in the form of an electric backup sump pump. This pump is installed in the same sump as the primary pump, but it only turns on if the primary pump fails. These pumps are battery-powered."
A backup is a stopgap, not a second main pump. The owner's manual for one backup system, the Flotec FPDC20, says it "is not a substitute for your primary sump pump" and "is designed to temporarily backup your primary sump pump during a power outage or other problem which prevents normal operation of the primary pump."
Battery backup sump pumps
A battery backup system pairs a backup pump with a battery and a charger that keeps the battery ready while the house has power. In the Flotec FPDC20 manual, that is a 12-volt lead-acid battery and a charger/controller. Where each part goes comes from the maker's installation guide, so follow yours.
The Flotec FPDC20 manual gives a typical example. It says to install the backup pump's float switch "1" above start water level of primary pump," so the backup only turns on when the main pump has not kept up. It says to "Keep battery charger and battery box off of the floor and in a dry, cool, well ventilated area," and warns, "To avoid danger of fire or explosion, keep sparks and flame (pilot light) away from battery."
The same manual says to test the full setup after installing it: "fill your pit with water and verify that the PSP removes the water and the BBU doesn't run. Then, unplug your PSP and refill your pit with water. Verify that the BBU pump removes the water." In that manual, PSP means the primary sump pump and BBU means the battery backup unit.
Which battery to use
NDSU Extension's quick tips for backup sump pump batteries are short:
- "Use a deep-cycle lead-acid battery with a backup sump pump."
- "The ampere-hour (AH) rating determines the hours of protection."
- "Purchase a battery with an AH rating near the maximum recommended by the backup sump pump manufacturer. Typically, it will be around 120 AH."
- "If the primary battery runs down in an emergency, a standard vehicle battery can be used to provide power to the backup sump pump."
Pump makers can be more specific, and they don't all agree on the type. The Flotec FPDC20 manual says the system "is designed to work with a deep cycle sealed maintenance free lead-acid AGM battery. It will also work with a flooded lead acid battery. Gell and Sealed flooded lead acid batteries are not recommended." It also says, "Use only lead-acid batteries," and lists a maximum of 120 amp-hours.
On car batteries, NDSU and Flotec agree that one can fill in during an emergency, but Flotec adds a warning. Its manual says your automobile battery "may be temporarily substituted," but "Automobile batteries are not designed for this type of application and will be quickly ruined by the repeated charge/discharge cycling." It also says, "An automotive battery may require charging after only 1-2 hours of continuous use." So a car battery is a fallback, not a plan.
How long a battery lasts depends on the battery, the pump and how often water comes in. For its own system, Flotec lists an approximate run time of 4.5 hours, or 3,000 gallons per charge at a 10-foot lift, with its 40 amp-hour battery, and 10.3 hours, or 7,000 gallons, with its 75 amp-hour battery. Those are Flotec's figures for the FPDC20 only, so check your own pump's manual for its numbers.
Maintenance and testing
A backup only helps if it works on the night you need it. NDSU Extension says to "Check every six months to ensure that the battery maintains an adequate charge and has no corrosion."
NDSU Extension's spring checklist for sump pumps gives these steps:
- "First make sure the discharge pipe on the outside of the house is not plugged and that it directs water away from the house."
- "Make sure the pump is plugged in. Remove the lid (if the sump has one) and use a flashlight to check that the sump doesn't contain any material that can plug the pump."
- "If the sump is dry, lift the float for about 10 seconds to see if the pump turns on and runs smoothly, then lower the float slowly. Briefly running a pump when it's dry will not do any damage."
- "If you have an electric backup pump, that can be checked the same way."
- Or pour water into the sump until the float turns the pump on, and watch and listen. "Make sure the pump turns on and off at least twice," NDSU's Ken Hellevang says. "If the pump sounds like it is pumping gravel or the float is sluggish, then you may need a new pump or float."
One pump maker sees the dry-run test differently. NDSU says briefly running a pump dry will not do any damage, while the Flotec FPDC20 manual says, "Do not run pump dry. To do so will damage seals and can cause leaking and property damage." If your manual warns against dry running, use the pour-water test instead.
Running the pump on a generator
A portable generator can keep the main pump going, as long as it is big enough and set up safely. The CPSC says, "Operate generators outdoors only, at least 20 feet from homes and buildings, with exhaust directed away from windows, doors and vents." Ready.gov says at least 20 feet away from windows, doors and attached garages. NDSU Extension gives no distance, but it is just as clear about where not to run one: "Carbon Monoxide poisoning is common after disasters due to the generator being in a building, even with the door open." The CPSC lists basements and garages by name. Our generator distance guide covers the distance rules and how they differ.
There are two ways to get power to the pump:
- Extension cords. Ready.gov says, "Always connect the generator to appliances with heavy-duty extension cords." NDSU Extension adds, "If using extension cords, assure that the wire is the appropriate size for the wattage," and warns, "A motor will 'burn-out' if the wire is too small or a long cord is used due to voltage loss in long cords or wires."
- A transfer switch. NDSU Extension says, "Do not connect the generator to a home or farm electrical system without a transfer switch that disconnects the farm or home from the power line and connects to the generator." The wiring has to be isolated with a double-throw transfer switch "to prevent the generator from feeding electricity back into the power line."
Sizing starts with the pump's label. NDSU Extension gives a rule of thumb: "As a guide, electric motors require approximately 4,000 watts of power to start and 1,000 watts of power to run for every horsepower of output." That is NDSU's guide, not a spec for your pump, so check your pump's label or manual for its horsepower and watts. Our power station vs generator comparison explains starting and running watts in general terms. A smaller apartment station is compared on our power station for a fridge or CPAP page; that roundup is not a sump-pump pick. Size any station or generator from your pump's label or manual. Our free power station size calculator can use those running and starting watts to estimate capacity.
Electrical safety in a wet basement
Water in a basement changes the rules. ESFI says, "Never touch electrical equipment that has been submerged as it may still be energized," and to "avoid entering flooded areas until power has been confirmed off by the electric utility." The CPSC says, "Do not touch wet appliances that are still plugged into an electrical source."
Sources differ on who turns the power off. FDA says, "If electrical circuits and electrical equipment have gotten wet, turn off the power at the main breaker." The Flotec FPDC20 manual says, "If basement floor is wet, disconnect power to basement before walking on floor," and "Do not plug in or unplug battery charger while standing on a wet floor or in water." None of those sources explains how to reach a breaker panel that is in the wet area. ESFI's rule covers that case: if getting to the panel means stepping into water, stay out and call your utility.
Two more rules apply to anything plugged in near water:
- GFCI protection. NDSU's Hellevang says "a ground-fault circuit interrupter must be used with all electrical use in a wet environment to prevent electrocution." The Flotec manual says a GFCI "is recommended for use on any electrical appliance submerged in water." NDSU says must, Flotec says recommended, and both point the same way.
- Keep the generator dry. Ready.gov says, "Keep the generator dry and protected from rain or flooding. Touching a wet generator or devices connected to one can cause electrical shock."
After a flood, the CPSC says to "have a qualified professional or utility representative inspect the home and replace all gas control valves, electrical wiring, circuit breakers and fuses that have been under water," and ESFI says, "Any equipment exposed to water must be inspected by qualified professionals before being returned to service."
Carbon monoxide alarms
Anyone running a generator needs working carbon monoxide alarms. Ready.gov says, "Install working carbon monoxide detectors on every level of your home." The CPSC says to install CO alarms, battery-operated or with battery backup, "on every level and outside sleeping areas at home."
One placement note is specific to battery backup pumps. The Flotec FPDC20 manual says, "If a Carbon Monoxide (CO) sensor is installed, it must be at least 15 feet away from battery charger in order to avoid nuisance CO alarms." Check your own pump's and alarm's manuals for spacing. Our generator distance guide covers carbon monoxide symptoms and alarms in more detail.
Gear that helps
What to look for: a battery backup sump pump whose maker lists maximum battery amp-hours and pumping rate, a matching 12-volt deep-cycle battery (NDSU, Flotec), a battery box kept off the floor (Flotec), a heavy-duty outdoor extension cord (Ready.gov, NDSU, CPSC), and a carbon monoxide alarm with battery backup (Ready.gov, CPSC). We list no generator here; see the generator distance guide.
Doom Signals earns from qualifying Amazon purchases.
A heavy-duty outdoor extension cord
For running the pump from a generator outdoors. Ready.gov says to use heavy-duty extension cords, and NDSU says the wire must be the right size for the wattage. This 25-foot 12/3 cord is outdoor-rated, which covers the CPSC's 20-foot generator distance.
Kidde COPD plug-in CO alarm with battery backup and display
Ready.gov and the CPSC say to put CO alarms on every level. Kidde says this alarm is tested to meet UL 2034 5th Edition, plugs into 120-volt AC, and uses two AA backup batteries. A backlit display shows CO levels.
Checked Wednesday, Nov 18, 2026, 8:35 AM ET. No prices listed because they change daily.
FAQ
- Will my sump pump work during a power outage?
- Not unless it has backup power. NDSU Extension says a battery backup pump in the same sump turns on only if the primary pump fails, such as in a power outage.
- How does a battery backup sump pump work?
- It is a battery-powered pump in the same sump as the main pump. In the Flotec FPDC20 manual, its float switch sits 1 inch above the main pump's start level, and a charger keeps the battery ready.
- What battery should I use for a backup sump pump?
- NDSU Extension says a deep-cycle lead-acid battery, with an amp-hour rating near the pump maker's maximum, typically around 120 AH. Some makers, such as Flotec, say AGM or flooded lead-acid, not gel.
- How long will a backup battery run the pump?
- It depends on the battery and how often the pump runs. Flotec lists about 4.5 hours with its 40 AH battery and 10.3 hours with its 75 AH battery, for its FPDC20 system only.
- Can a generator run my sump pump?
- Yes, if it can handle the pump's starting load. Keep it outdoors, at least 20 feet from the house (CPSC). Use heavy-duty extension cords (Ready.gov) or a transfer switch (NDSU Extension).
- Can I run the generator in the basement or garage to be near the pump?
- No. NDSU Extension says carbon monoxide poisoning is common when a generator runs in a building, even with the door open, and the CPSC names basements and garages.
- Is it safe to go into a flooded basement?
- ESFI says avoid entering flooded areas until the electric utility confirms the power is off, and never touch submerged electrical equipment.
- How often should I test my backup pump?
- NDSU Extension says to check the battery every six months for charge and corrosion, and that a backup pump can be tested the same way as the main pump, by lifting the float.
More outage guides: what to do during a power outage, how far a generator should be from the house, power station vs generator and our power outage kit list. All of them are on our guides page. To get the next guide by email, subscribe here. How we pick and check sources is on our methodology page.
Sources
- NDSU Extension, Electric Backup Sump Pumps for Houses: Quick Tips for Battery Selection (PDF, Feb. 2020)
- NDSU Extension, Now is the time to check your sump pump (March 21, 2022)
- NDSU Extension, NDSU Extension offers guidance amidst power outages and flooding (April 28, 2022)
- CPSC, CPSC Warns of Generator, Carbon Monoxide and Fire Hazards Ahead of Hurricane Season (May 27, 2026)
- Ready.gov, Power Outages (last updated June 4, 2026)
- ESFI, Flooding and Disaster Safety (April 30, 2026)
- FDA, FDA Offers Tips about Medical Devices and Natural Disasters
- Pentair Flotec, FPDC20 Battery Backup System owner's manual (PDF, 2014)
- Maker: Kidde COPD
Image: Marvin Nauman, FEMA (public domain).
All guidance checked Saturday, Nov 14, 2026, 1:05 AM ET.